Cold storage real estate operates under a different set of economics than conventional warehouse space. The capital intensity, operating costs, and tenant requirements create a distinct investment and occupancy profile that owners, occupiers, and investors must understand before entering this segment of Metro Vancouver's industrial market.
This post examines the financial mechanics and site selection factors that shape cold storage decisions in the region, complementing the broader coverage of Metro Vancouver industrial market conditions and food and beverage facility requirements already published on this site.
Capital Requirements and Development Economics
Cold storage facilities require substantially more capital than dry warehouse buildings of equivalent size. The gap stems from several factors that compound during development and persist through operations.
Refrigeration systems represent the most obvious cost premium. A typical cold storage facility requires insulated panel construction, vapour barriers, specialized flooring to prevent frost heave, and mechanical systems capable of maintaining temperatures ranging from blast freezing at negative thirty degrees Celsius to controlled produce storage at two to four degrees. The mechanical plant alone can represent a significant multiple of the HVAC cost for a comparable dry warehouse.
Electrical infrastructure follows closely. Refrigeration compressors draw substantial power continuously, requiring upgraded service, redundant systems for food safety compliance, and often backup generation. Many older industrial buildings in Metro Vancouver lack the electrical capacity to support a cold storage conversion without costly service upgrades.
These capital requirements influence both development patterns and lease economics. Purpose-built cold storage facilities are typically developed under long-term lease commitments with creditworthy tenants, or by owner-occupiers with the balance sheet to absorb the upfront investment. Speculative cold storage development is rare because the capital at risk is too high and the tenant pool too specialized to leave a building empty.
Operating Cost Structures
Beyond the initial capital outlay, cold storage facilities carry operating costs that differ substantially from conventional industrial space. Understanding these costs is essential for accurate underwriting on both sides of a lease or sale transaction.
Electricity dominates operating expenses. Refrigeration systems run continuously, and energy costs scale with temperature requirements. A frozen storage facility at negative twenty degrees consumes considerably more power than a produce cooler at plus two degrees. BC Hydro's industrial rates provide some cost advantage compared to other jurisdictions, but electricity still represents a material operating expense that tenants must budget carefully.
Maintenance requirements are more demanding than for dry warehouses. Refrigeration systems require specialized technicians, and equipment failures carry immediate consequences for inventory integrity. Prudent operators maintain service contracts and spare parts inventories that add to fixed costs.
Insurance premiums reflect the value at risk. A cold storage facility may hold millions of dollars in perishable inventory, and an extended power failure or refrigeration breakdown can result in total loss. Property and business interruption coverage is priced accordingly.
For tenants evaluating occupancy costs, the net rent is only the starting point. With average net asking rents in Richmond averaging about $20.26 PSF and additional rent typically running $6 to $7 PSF across Metro Vancouver, a cold storage tenant must layer substantial utility and maintenance costs on top. The total occupancy cost for a refrigerated facility can exceed the gross occupancy cost of a dry warehouse by a considerable margin, depending on temperature specifications and equipment age.
Site Selection Factors
Cold storage operators evaluate sites against criteria that differ from conventional warehouse users. Several factors merit particular attention in Metro Vancouver.
Electrical service capacity often determines feasibility before any lease negotiation begins. A building with inadequate service may require a BC Hydro infrastructure upgrade that adds months or years to the project timeline and significant capital cost. Buildings in older industrial areas, including portions of Vancouver and Burnaby, may face constraints that make conversion impractical.
Roof structure matters because refrigeration equipment is heavy and often roof-mounted. Clear span construction with adequate structural capacity is essential, and some older buildings cannot support the mechanical loads without reinforcement.
Floor conditions require careful inspection. Existing slabs without adequate insulation or vapour barriers will develop frost heave problems under freezer conditions. Remediation can be expensive and disruptive.
Transportation access aligns with cold chain requirements. Food distributors serving retail and food service customers across Metro Vancouver typically prioritize central locations that minimize delivery distances. Richmond has emerged as a natural hub for cold storage activity due to its central position, highway access, and proximity to both population centres and the port. Submarket profiles can help operators understand the trade-offs across different areas.
Zoning compatibility requires verification. Cold storage facilities may involve 24-hour operations, truck traffic, and ammonia-based refrigeration systems that require additional permitting. Not all industrial zones accommodate these uses without variance or conditional approval.
Lease Structures and Tenant Considerations
Cold storage leases often reflect the specialized nature of the asset and the relationship between landlord and tenant capital contributions.
Lease terms tend to be longer than average. Because landlords may invest substantial capital in refrigeration infrastructure, or because tenants invest in fit-out that cannot be economically relocated, both parties typically seek terms of seven to fifteen years or longer. This provides amortization runway for capital investments.
Improvement ownership and removal provisions require careful negotiation. Refrigeration systems represent substantial value, and the lease should specify clearly whether improvements become landlord property at lease end, whether the tenant has removal rights, and what restoration obligations apply. These provisions affect both parties' financial positions at lease expiry.
Base rent structures may differ from conventional deals. Some landlords build refrigeration capital into higher base rents. Others prefer a shell rent with the tenant responsible for all refrigeration capital. The economic outcome depends on the specific numbers, but tenants should model total occupancy cost over the lease term rather than comparing base rents alone.
For a detailed treatment of lease mechanics, the net lease versus gross lease guide provides foundational context applicable to all industrial tenancies including cold storage.
Investment Considerations
Cold storage assets present a distinct investment profile that appeals to some capital sources and not others.
Tenant credit quality matters more than in conventional industrial. The specialized nature of the improvements means that re-leasing a cold storage facility to a new tenant often requires the new occupier to have similar requirements. If the existing tenant fails and the facility must be marketed broadly, conversion to dry warehouse use may be the only practical option, eliminating the premium value of the refrigeration infrastructure.
Replacement cost provides meaningful downside support. Cold storage facilities are expensive to build, and the specialized construction creates barriers to new supply. This dynamic can support pricing even in softer market conditions.
Operating complexity exceeds typical industrial ownership. Investors must either develop refrigeration expertise in-house, engage specialized property management, or rely on tenant-maintained systems with appropriate lease protections. The asset class is not suitable for passive ownership without competent operating oversight.
For investors evaluating cold storage opportunities against other industrial options, the guide to selling industrial property addresses underwriting and disposition considerations that apply across asset types.
Market Context
Cold storage demand in Metro Vancouver reflects the region's role as Western Canada's primary distribution gateway and its substantial population base requiring food distribution infrastructure.
Purpose-built cold storage inventory is limited relative to demand. Most available options involve existing facilities rather than new construction, and tenants seeking large blocks of refrigerated space often face extended searches. The constrained supply supports rent premiums above conventional warehouse rates, though transaction volume is too thin to publish reliable averages.
Conversion of existing dry warehouses to cold storage occurs selectively, but the technical requirements described above limit the pool of suitable candidates. Buildings constructed in recent decades with adequate power, modern clear heights, and structurally capable roofs offer the best conversion potential.
Taking a Practical Approach
Cold storage real estate rewards careful analysis of capital requirements, operating costs, and site-specific constraints. For occupiers, the right facility can support efficient cold chain operations across Metro Vancouver. For investors, the asset class offers specialized exposure with meaningful barriers to entry.
Whether you are evaluating a cold storage lease, considering a build-to-suit, or assessing an investment acquisition, the starting point is understanding how the economics differ from conventional industrial space. NAI Commercial Vancouver works with occupiers and investors navigating these decisions, drawing on local market knowledge and NAI Global's network of industrial specialists. For more information or to discuss a specific requirement, please contact our team.
Sources
- CBRE: Vancouver Industrial Figures, Q2 2026 (published 2026-07-28)
- Colliers: Vancouver Industrial Market Report, Q2 2026 (published 2026-07-10)
- Cushman & Wakefield: Vancouver Industrial MarketBeat, Q2 2026 (published 2026-07-02)
- Avison Young: Metro Vancouver Industrial Market Report, Q2 2026 (published 2026-07-15)